After a containerized or skid-mounted reverse-osmosis plant is in service, availability depends less on a new civil works campaign than on a short list of wearing parts and consumables. This page summarises GUANYA WATER SOLUTION’s general selection guide for seawater and brackish RO systems. A project-specific spare-parts list is issued with each quotation and after detailed design. Intervals below are typical planning values, not guarantees; actual replacement follows differential pressure, normalized performance and the plant manual.
Recommended categories
| Category | Typical items | Typical planning interval |
|---|---|---|
| Cartridge filter elements | PP melt-blown cartridges, 5 µm (and 1 µm where fitted) | Replace every 1–3 months, or when differential pressure rises by about 0.5–1.0 bar |
| Membrane maintenance | Acid and alkaline cleaning chemicals, biocide; spare O-rings and brine seals for membrane elements | Clean according to normalized data (about a 10–15% flow drop, or a 10% rise in salt passage); O-rings with each membrane replacement |
| Dosing system | Dosing-pump head or diaphragm, injection valves, antiscalant | Diaphragm around 1 year; antiscalant according to consumption |
| UV disinfection (where fitted) | UV lamp, quartz sleeve, lamp ballast | Lamp every 8,000–12,000 hours |
| Valves and instruments | Solenoid or motorized valve seals, pressure gauges and switches, conductivity electrodes | As needed; electrodes typically 1–2 years for calibration or replacement |
| Pump wear parts | Mechanical seals and impeller wear rings for feed and high-pressure pumps | Mechanical seals often 1–2 years, depending on duty |
| Filter media (where media filters or a softener are fitted) | Quartz sand, activated carbon, softener resin and salt | Sand/carbon 2–3 years; resin 3–5 years; salt according to consumption |
| Electrical and control | Fuses, relays, indicator lamps, HMI backup battery | As needed |
High-pressure pump seal and valve kits, and membrane and cartridge holdings for one or two years of operation, are usually listed separately on a project spare quotation. Lubricating-oil grade, where relevant, is confirmed against the supplied pump nameplate.
One-year and two-year packages
One-year and two-year spare-parts packages can be added to an order. They are optional. A two-year holding typically concentrates on cartridges, membranes or UF modules (if the plant has UF), and other items with a predictable consumption rate. Critical pump internals may be offered as a separate strategic kit rather than being mixed into the consumables package. None of these packages replaces correct operation, pretreatment or chemical dosing.
Operating chemicals (antiscalant, CIP chemicals, biocide and any disinfection chemicals) are usually supplied by the owner. GUANYA can provide dosing guidance and recommended brands on request. See the companion article on chemical dosing and CIP.
How to order
Send the system reference number on the equipment nameplate to the export team at [email protected]. GUANYA confirms exact part numbers and, where needed, cross-references alternatives. Do not order from a generic catalogue description alone: housing length, end-cap type, membrane model and pump series must match the built plant.
This page does not publish list prices or a single global lead time. Those figures are given on the project quotation and depend on the item (stock versus indent) and the shipping method to the site.
What this page does not claim
GUANYA does not claim a worldwide consignment warehouse or a permanent in-country parts partner in every market. For remote island and camp plants, the practical approach is to hold a documented first-year or two-year kit on site, keep the nameplate reference, and use remote support to diagnose which part is actually required before an urgent air shipment.
For a spare-parts list against an existing plant or a new quotation, include the nameplate reference, a recent photo of the skid or container tag, and any differential-pressure or normalized-performance data already recorded.