GUANYA WATER SOLUTION has prepared a 40 ft high-cube, containerized seawater reverse-osmosis (SWRO) design for an island hotel in Fiji. The design product flow is 15 m³/h. At 20 operating hours per day, daily supply is about 300 m³.
This page is not a description of the Fiji island-resort SWRO units that GUANYA has already shipped. Those shipped cases remain labelled separately. The hotel name is withheld.
Country: Fiji | Duty: Island-hotel drinking water | Design flow: 15 m³/h (300 m³/day at 20 h)
The problem
An island hotel in Fiji needed a containerized seawater RO plant rated 15 m³/h, or 300 m³/day at 20 operating hours, to supply hotel drinking water. This treatment scheme is distinct from GUANYA’s already-shipped Fiji island-resort SWRO cases, which are published on separate pages.
How the scheme solves it
GUANYA prepared a 40 ft high-cube seawater RO treatment scheme. The process flow in the project description is raw-water boost → coagulant dosing and mixing → multimedia filtration → cartridge filtration → antiscalant dosing → a seawater RO train of SW400GR elements (25 elements, five pressure vessels with five elements each, one stage, 40% design recovery) → product boost, UV disinfection, remineralization and residual disinfectant. Design permeate flow is 15 m³/h. The RO train is shown with a high-pressure pump of 38 m³/h at 60 bar in the process figure. A CIP loop is included and is used only during chemical cleaning.
The general arrangement places a sand filter, dosing tanks, cartridge filter, high-pressure pump, membrane array, control cabinet, CIP tank and ventilation in the 40 ft container. The unit is factory-assembled and factory-tested; time to first water depends on intake, power, storage and site hook-up.
Design drawings


Design basis
| Item | Design-basis value |
|---|---|
| Country / setting | Fiji, island hotel (identity withheld) |
| Design product flow | 15 m³/h; about 300 m³/day at 20 operating hours |
| Design feed | Open seawater intake, TDS 36,006 mg/L, pH 8.00, SDI < 5 |
| Design recovery | 40% (adjustable in the design between 35% and 45% at the concentrate valve) |
| Feed flow at 40% recovery | 37.5 m³/h |
| RO permeate TDS (calculation) | 118 mg/L, salt rejection 99.67% — calculation figures only, not field measurements |
| Product post-treatment (design targets) | After UV, remineralization and disinfection: hardness 40–80 mg/L as CaCO₃, pH 7.5–8.0, residual chlorine 0.5–1.0 mg/L, TDS 200–400 mg/L. These are commissioning targets, to be set against the actual permeate and the hotel network. |
| RO array (design) | 25 seawater membrane elements, five pressure vessels, five elements per vessel, one stage / one pass |
| Integration | Process equipment, dosing, electrical control and ventilation in one 40HQ container, factory-assembled and wet-tested. On site the design connects intake, product, drain and a 415 V supply. Time to first water depends on those interfaces. |
The proposed train is raw-water boost → multimedia filtration → cartridge filtration and antiscalant → high-pressure SWRO → UV, remineralization and disinfection into the hotel network. Concentrate leaves the module at the flow implied by the 40% recovery. A lawful discharge path remains the owner’s responsibility.
Related reading
- Containerized SWRO for a Fiji island resort (shipped; operating results not published as measured performance)
- Cambodia island-hotel SWRO upgrade, 5 m³/h
- Factory acceptance and commissioning
Frequently Asked Questions
Is this the same as GUANYA’s already-shipped Fiji plants?
No. This page describes a treatment scheme for a 15 m³/h hotel duty. Shipped Fiji SWRO cases are published on separate pages and remain labelled as shipped, with operating results not published as measured performance.
How is the 300 m³/day figure derived?
It is 15 m³/h at 20 operating hours. Actual daily output depends on operating hours, feed quality, cleaning and downtime.