GUANYA WATER SOLUTION logo

GUANYA WATER SOLUTION

Blog

Home > Blog

Containerized SWRO Upgrade for an Island Hotel in Cambodia | 5 m³/h Design

GUANYA WATER SOLUTION has prepared a containerized seawater reverse-osmosis (SWRO) design to replace an aging desalination plant at a remote island hotel in Cambodia. The current design is two trains of 2.5 m³/h, or 5.0 m³/h together. At 20 operating hours per day, that is a planning figure of 100 m³/day of drinking water. The hotel and site names are withheld.

Country: Cambodia | Duty: Island-hotel drinking water, replacement of an end-of-life SWRO plant | Design flow: 5.0 m³/h (100 m³/day at 20 h)

The problem

A remote island hotel in Cambodia needed a reliable drinking-water supply of about 80–100 m³/day to replace an aging seawater RO plant. The existing unit was described as aged, short of capacity, and affected by dissolved organic matter and biological slime that fouled cartridges and RO membranes. Existing ultrafiltration and RO equipment were not to be reused. The drinking-water target is the WHO Guidelines for Drinking-water Quality and Cambodia’s national drinking-water standard. The hotel and site names are withheld.

How the scheme solves it

GUANYA prepared a dual-train, containerized UF + seawater RO treatment scheme: two trains of 2.5 m³/h, or 5.0 m³/h together (a planning figure of 100 m³/day at 20 operating hours). The process is coagulant (PAC) mixing → existing seawater buffer tanks → multimedia filtration → manganese-sand filtration → cartridge filtration → ultrafiltration (ten modules, five per train, with automatic backwash) → UF product tank → seawater RO in two trains, with CIP and a shutdown flush. Product disinfection is ultraviolet plus residual chlorine in the hotel network. Intermittent biocontrol is used in pretreatment; continuous pre-chlorination is not the selected route in this design.

Single-train RO feed in the 37% recovery projection is 6.76 m³/h, with 2.5 m³/h of permeate. Design feed TDS is up to 36,000 mg/L; membrane projections were also run at about 31,000 mg/L (25 °C) and 36,000 mg/L (32 °C). A design water balance after flush and CIP gives about 99 m³/day delivered to the existing product tanks if the plant is run for 20 hours. The process equipment is integrated in one 40 ft high-cube container, factory-assembled and factory-tested. Field work is hook-up of water, power and external interfaces; time to first water depends on site conditions. Seawater intake structures, civil works and existing tanks remain in the owner’s scope unless a later contract says otherwise.

Design drawings

Process flow diagram for a dual-train containerized seawater RO scheme for an island hotel in Cambodia, including coagulation, multimedia and manganese-sand filtration, ultrafiltration, reverse osmosis and product disinfection.

Process flow for the Cambodia island-hotel SWRO scheme (design drawing, not a photograph of a built plant).

Plant-room layout drawing for a Cambodia island-hotel seawater RO upgrade, showing pretreatment, two ultrafiltration and RO trains and existing product tanks inside a 40 ft high-cube container footprint.

Equipment layout for the Cambodia island-hotel SWRO scheme (design drawing, not a photograph of a built plant).

Design basis

The owner asked for 80–100 m³/day of net drinking water, to be compared with repairing the existing plant. The existing unit was described as aged, short of capacity, and affected by organic matter and biological fouling. Existing ultrafiltration and RO equipment were not to be reused. The drinking-water target is the WHO Guidelines for Drinking-water Quality and Cambodia’s national drinking-water standard.

Item Design-basis value
Country / setting Cambodia, remote island hotel (identity withheld)
Design treatment flow Two trains of 2.5 m³/h, 5.0 m³/h together
Planning daily output 100 m³/day at 20 operating hours. A design water balance, after flush and CIP, gives about 99 m³/day delivered to the existing product tanks. If operating hours are shorter, that daily figure does not apply automatically.
Design feed Seawater, design TDS up to 36,000 mg/L. Membrane projections were also run at about 31,000 mg/L (25 °C) and 36,000 mg/L (32 °C).
Design recovery (projections) 37% and 42% in the two membrane-projection cases. These are design calculations, not operating results or contract guarantees.
Product water (design) Permeate TDS not higher than 500 mg/L before remineralization, under the agreed feed and stable operation. Chloride and TDS guarantees for contract purposes remain subject to a final feed analysis.
Integration One 40 ft high-cube container, factory-assembled and factory-tested. Field work is hook-up of water, power and external interfaces. Time to first water depends on site conditions.

Related reading

Frequently Asked Questions

How is the 100 m³/day figure derived?

It is a planning figure: 5.0 m³/h at 20 operating hours. A design balance after flush and CIP is about 99 m³/day to the existing tanks. Shorter operating hours would reduce daily output.

Why does the design include ultrafiltration?

The existing plant was reported to suffer from dissolved organic matter and biological slime that fouled cartridges and RO membranes. The proposed train places coagulation, multimedia and manganese-sand filtration and ultrafiltration ahead of the seawater RO.

Share To:
products
products
All
Water Filter System
Containerized mine water treatment 40HQ BWRO module at a high-altitude copper mine
Containerized Mine Water Treatment Systems: BWRO & Wastewater Reuse
Containerized SWRO system for data center cooling tower makeup water
Seawater Desalination for Data Center Cooling: Containerized SWRO Systems
Containerized RO system built for a hot desert environment
Containerized Industrial RO Systems – Oil & Gas, Power Plants, Industrial Facilities
06-solar-powered-desert-water-solution-800x800
Containerized Brackish Water Desalination for Desert Camps – Solar-Ready
Containerized mining water treatment system at a high-altitude camp
Compact Brackish Water RO for Exploration and Small Mining Camps
A55
Electroplating Solution Recovery System With Low Temperature Evaporator
11_Pacific_Island_Community
Island Community Containerized Desalination System | Affordable Community RO Plant
Illustration of a containerized industrial wastewater treatment system for water reuse
Advanced Treatment Systems for Industrial, Mining and High-Strength Wastewater Applications
11
Copper Mining Wastewater Treatment & Water Reuse System for Chile
Solar containerized mining water treatment system at a mining camp
Containerized Water Supply Systems for Remote Mining Camps
1 2 3 4

Contact Us Anytime

Contact Us Anytime

Send Us a message